BURNERS & HOT WATER BOILERS & AUTOMATIC SOFTENERS
" Lamborghini " Italy (ISO9001) " CE Standard "
 
1.Gas / Light oil / Heavy Oil Burners
1.1) Gas Burner (LPG & Natural Gas & Bio - Gas)
1 stage, 2 stage & Modulation Burner
Heat Output : 12 - 4,275 kW
                   : 10,235 - 3,676,000 kcal/hr.
Gas Flow - rate (Natural Gas) : 1.2 - 430 m3/hr.

1.2) Light oil (Diesel) Burners
1 stage, 2 stage & Modulation Burner
( Hinge opening for combustion head adjustment )
Heat Output : 16 - 3,558 kW
                        : 14,000 - 3,060,000 kcal/hr.
Light Oil Flow - rate : 1.3 - 300 kg/hr.

1.3) Heavy Oil Burners
1 stage, 2 stage
( Hinge opening for combustion head adjustment )
Heat Output : 80 - 3,418 kW
                        : 68,000 - 2,940,000 kcal/hr.
Heavy Oil Flow - rate : 7 - 300 kg/hr.

1.4) Dual Fuel Burners ( Light Oil & Gas Burners)
1 stage, 2 stage
Heat Output : 80.7 - 1,993 kW
                        : 69,400 - 1,713,980 kcal/hr.
Light Oil Flow - rate : 6.8 - 168 kg/hr
Gas Flow - rate ( Natural Gas ) : 8.1 - 200 m3/hr.


2.Hot Water Boiler ( Gas & Diesel Fuel )
2.1) Steel Body Hot Water Boiler ( Stainless Steel Tube )
Rang of Water Temperature : 40 - 95°C ( adjustable )
Flow rate of Hot Water ( Calculate at 70°C ) : 414 - 51,600 L/hr.
Type of Fuel by Burners : Gas (LPG/Natural Gas/Bio-Gas) & Light Oil (Diesel )
Heat Output : 24 - 3,000 kW
                              : 20,000 - 2,580,000 kcal/hr.
Estimate Dimension :
  Wide x Length x High ; 450 x420 x850 to 600 x3,855 x1,890 mm.

2.2) Cast Iron Body Hot Water Boiler (Stainless Steel Tube)
Rang of Water Temperature : 40 - 95°C ( adjustable )
Flow rate of Hot Water ( Calculate at 70 C ) : 360 - 4,558 L/hr.
Type of Fuel by Burners : Gas (LPG/Natural Gas/Bio-Gas) & Light Oil (Diesel )
Heat Output : 21 - 265 kW
                            : 17,970 - 227,900 kcal/hr.
Estimate Dimension :
  Wide x Length x High ; 450 x420 x850 to 600 x1,520 x1,080 mm.

2.3) Wall Hang Hot Water Boiler
Rang of Water Temperature : 40 - 95°C ( adjustable )
Flow rate of Hot Water ( Calculate at 50 C ) : 250 - 6,000 L/hr.
Type of Fuel : Gas (LPG/Natural Gas/Bio-Gas)
Heat Output : 8.8 - 206 kW
                      : 7,568 - 177,160 kcal/hr.
Estimate Dimension :
  Wide x Length x High ; 350 x230 x760 to 1,270 x760 x1,675 mm.

3. Hot Water accumulator for Spa, Hotel, Hospital and Big House (Used with Hot Water Boiler)
Rang of Water Temperature : 40 - 80°C ( adjustable )
Flow rate of Hot Water ( Calculate at 50°C ) : 816 - 2,963 L/hr.
Type of Fuel by Burners : Gas (LPG/Natural Gas/Bio-Gas) & Light Oil (Diesel )
Exchange Heat Output : 28.5 - 89.7 kW
                                                      : 24,500 - 77,150 kcal/hr.
Estimate Dimension :
  Wide x Length x High : 450 x600 x610 to 750 x1,375 x1,950 mm.


4. Automatic Softener (analog & digital Control System)
Flow rate of Hot Water : 600 - 32,000 L/hr.
Max. Presser : 7 Bar

Estimate Dimension of Cylinder : Diameter x High : 260x1,335 to 900x2,450 mm.

Estimate Dimension of Salt Container :
Wide x Length x High ; 330 x210 x740 to 1,265 x1,265 x1,350 mm.